Solar plants inspected through imagery

Soiling, cracked modules and loose wiring identified in drone photos and videos, with a maintenance ranking and estimated generation loss.

Solar Panel Inspection

Soiling, cracked modules and loose wiring in solar plants and rooftop arrays

The AI cuts out each photovoltaic panel from the image (drone, fixed camera or inspection photo) and checks for the non-conformities that hurt a plant's generation and safety the most: soiling (dust, bird droppings, leaves, snow), cracked glass or broken modules, and loose or exposed wiring. Each panel gets a status (Compliant, Soiling X%, Broken, Exposed wiring), generation loss is estimated and panels are ranked by maintenance priority — the O&M team goes straight to the modules that most need cleaning or replacement.

How it works

  1. 1Panel segmentation (YOLO11-seg): the outline of each module/table is cut out; in drone video each panel is tracked and counted only once.
  2. 2Defect segmentation (YOLO11-seg): dust, bird droppings, leaves and physical damage are cut out in the actual shape of the stain. Only what is INSIDE the panel counts — surrounding ground and roof are ignored.
  3. 3A second detector adds snow and confirms damage; CLIP (vision-language, no training) compares each panel with descriptions of clean, dirty, snow-covered and broken panels — damage is only confirmed with two votes.
  4. 4Soiling = % of the panel area covered by stains (dust, droppings, leaves, snow). For snow, coverage is measured by the panel's white pixels.
  5. 5Loose/exposed wiring: text-prompted detection (OWLv2) of hanging cables, loops and loose coils near the modules or on the structure.
  6. 6Estimated generation loss: proportional to the soiled area (see assumptions); a broken panel assumes the configured loss (default 33%, one of the three bypass diodes of a typical module).
  7. 7Maintenance ranking: broken panels and exposed wiring first (safety), then the panels with the highest estimated loss.
YOLO11-seg (panels and defects — Solar Panel Inspection, CC BY 4.0)YOLO11 (snow and damage — solar-panel-od, MIT)CLIP zero-shot (confirmation)OWLv2 (text-prompted wiring detection)ByteTrack tracking

Benefits

  • On-demand cleaning — only on panels/tables with relevant soiling, instead of a fixed schedule.
  • Cracked modules identified early, before they become hot spots, water ingress or a fire risk.
  • Loose wiring found before it causes arcing, abrasion wear or string downtime.
  • Per-panel photographic evidence, with status and ranking, ready for the work order.
3–7%
Energy recovered through targeted cleaning
-60%
Field inspection time
-30%
Cleaning cost
24/7
Continuous monitoring

Generation loss from soiling is assumed proportional to the covered area (1% of area covered ≈ 1% loss) — a simplification: fine translucent dust loses less than that, while opaque stains over a cell (droppings, leaves) can trigger the bypass diode and lose more. A broken panel assumes the configured loss (default 33%). Exposed wiring is not included in the loss: it is a safety risk. Inspection is visual (RGB): internal microcracks and hot spots require electroluminescence or thermography (see Thermographic Analysis). Pre-trained models — "Solar Panel Inspection" (wcahca, CC BY 4.0, Roboflow data CC BY 4.0) and "solar-panel-od" (4keles, MIT); calibration with images from the plant itself is recommended before operational use.

Transmission Line Inspection

Outlines towers and cables in drone video and pulls out a photo of each tower seen up close during the flight

For power utilities and line maintenance companies. The video the drone already records during inspection goes through the system, which outlines towers and cables and pulls out a photo of each tower seen up close, with the moment of the flight. The crew reviews the structures from the list, without watching hours of video.

How it works

  1. 1Upload the flight video, or connect the drone's live feed. Every second the system outlines towers, poles and cables.
  2. 2Pieces of the same tower are merged into one, and when a tower fills a good part of the image (40% of the height by default) a notice with the photo comes out: it is the index of the towers seen up close.
  3. 3Tested on drone videos of forests, mountains and wetlands: towers were found in all of them. A thin, distant cable may be missed, and a tower's shadow on the ground is sometimes marked as a tower.
  4. 4Not included yet: vegetation near the cable (by color, the grass of the cleared strip looks like tree canopy) and broken or dirty insulators. Both are under development.
RF-DETR Seg trained by Neural (Apache 2.0)Outlines towers, poles and cablesDrone video, no extra equipment

Benefits

  • Drone inspection report without watching hours of video: one photo per tower seen up close, with the moment of the flight.
  • Towers and cables outlined frame by frame, to check the stretch that was flown.
  • History per flight to compare the same line from one inspection to the next.
All industries

Have a use case in mind? Send a video and get a free analysis.

Send us a video clip of your operation: we process it with our AI and return the results with detections, alerts and metrics — no strings attached.